Product Lifecycle
Firmware Version History
Firmware updates are provided through the FrontPanel Application. Please see the Firmware Updates page for instructions on updating your device firmware. You will need to have a valid Pins registration and be approved for firmware downloads.
VERSION | PCB Rev | RELEASE NOTES |
---|---|---|
1.46 | EXX | Removed VADJ options below min supported bank voltage |
1.42 | EXX | Added support for revision EXX |
1.31 | Up to DXX | Fix low probability configuration failures |
1.30 | Up to DXX | Fix an issue related to replacing obsolete Micron SPI flash with Cypress flash |
1.29 | Up to DXX | Improve firmware reliability in the case where USB is disconnected mid-transfer or the host aborts an active transfer |
1.26 | Up to DXX | Initial firmware release |
PCB Version History
REVISION | DETAIL |
---|---|
20151229 | First production PCB. |
CXX (date code 20171023) | Update host interface power supplies, update backup battery circuit. |
DXX | Update VCCINT power plane configuration. |
EXX | Replace EOL Enpirion power supply modules. See PCN-10108A. Disable FPGA internal I/O pullup resistors at startup. See PCN-10108B. |
FXX | Manufacturing updates. No impact to functionality. |
The PCB revision is identified in the board silkscreen.
Rev EXX
- The silk designator positions for R101 and R131 are reversed
- The silk designator positions for R124 and C194 are reversed
- The silk designator positions for C239 and C240 are reversed
Product Change Notifications
Product Change Notifications (PCN) are issued if a change to the product results in a change of mechanical or electrical behavior or reliability.
- PCN-10108A – Replace EOL Enpirion power supply modules.
Issue Date: 2022-03-31 - PCN-10108B – Disable FPGA internal I/O pullup resistors at startup.
Issue Date: 2022-03-31 - PCN-FW1.46+ – Minimum and default VADJ updated.
Issue Date: 2022-06-22