SYZYGY Ports
The XEM7320 provides 2x SYZYGY Standard ports and 1x SYZYGY Transceiver (TXR, not TXR4) port to connect to a variety of SYZYGY peripherals.
Documentation and Reference Materials
| XEM7320 Pins Reference | The interactive Pins reference for the device provides detailed pinout information as well as automated constraint file generation. Export functionality is provided to PDF, CSV. Constraint files are provided in XDC format for use in Vivado. |
| SYZYGY Specification | Further information and specification standard for SYZYGY ports. |
| SYZYGY GitHub | Open source SYZYGY tools and peripheral PCB template design files. |
| SYZYGY Design Guide | Design guide for connecting custom hardware to SYZYGY ports, or creating SYZYGY peripherals. |
Port Summary
| Physical PORT | SYZYGY PORT | SYZYGY TYPE | SMARTVIO GROUP | REFDES | bank |
|---|---|---|---|---|---|
| PORT A | SYZYGY 0 | Standard | 1 | J4 | I/O: 13 |
| PORT B | SYZYGY 1 | Standard | 2 | J5 | I/O: 34 |
| PORT C | SYZYGY 2 | Transceiver (TXR) | 3 | J6 | MGT: 216 (REFCLK0) I/O: 35 |
Port Power
Software controlled dc-dc regulators power the three SYZYGY SmartVIO groups as assigned above. The behavior of these power supplies is determined by the XEM7320_SMARTVIO_MODE parameter in Device Settings and associated settings. The modes function as described below.
Note that, for modes that require a SmartVIO solution, if any peripheral provides non-compliant DNA, a SmartVIO solution cannot be reached for all groups.
- SmartVIO only – SmartVIO is tested collectively so all present SmartVIO peripherals must result in a collective validation for any of the outputs to be enabled.
- SmartVIO hybrid mode – Each group is individually tested for SYZYGY peripherals. Within each group, if a SYZYGY peripheral is present (via detection of compliant DNA data) on any of the ports within that group, the SmartVIO solution is used to determine the voltage setting. If no SYZYGY peripherals are detected within the group, then the corresponding Device Setting (e.g.
XEM7320_VIO1_VOLTAGE) is used. - Device Settings only – SmartVIO settings from the peripherals are ignored, only the device settings are used. Also note that, in this mode, SYZYGY peripheral discovery is not performed so the corresponding device settings that identify each peripheral are not populated.
Peripheral Mounting
SYZYGY peripherals can be mechanically connected together using the carrier and peripheral mounting holes. Below are some suggested mounting hardware options. The Standard Hardware mounting kit is available from the accessories section of our store.
| PART | SUPPLIER | PART NUMBER | QUANTITY PER PORT |
|---|---|---|---|
| 5mm Unthreaded Standoff | McMaster-Carr | 94669A098 | 2 |
| Pan Head Phillips 10mm Bolt | McMaster-Carr | 92000A106 | 2 |
| Hex Nut | McMaster-Carr | 91828A113 | 2 |
| PART | SUPPLIER | PART NUMBER | QUANTITY PER PORT |
|---|---|---|---|
| Male-to-Female 5mm Standoff | McMaster-Carr | 93655A001 | 2 |
| Pan Head Phillips 4mm Bolt | McMaster-Carr | 92000A102 | 2 |
| Thumb Nut | McMaster-Carr | 96445A320 | 2 |
SYZYGY Compatibility Table
|
PARAMETER |
PORT A |
PORT B |
PORT C |
|---|---|---|---|
|
Total 5V Supply Current |
2.5 A |
||
|
Total 3.3V Supply Current |
4 A |
||
|
Port Groups |
Group 1: A |
Group 2: B |
Group 3: C |
|
Port Type |
Standard |
Standard |
Transceiver (TXR) |
|
Bank Type |
HR |
HR |
HR + GTP |
|
VIO Supply Voltage Range |
1.2 – 3.3 V |
1.2 – 3.3 V |
1.2 – 3.3 V |
|
Total VIO Supply Current |
2 A |
4 A |
2 A |
|
Port Spacing |
Double-Wide Spacing |
Single-Wide |
|
|
I/O per Port |
28 total (8 DP) |
28 total (8 DP) |
18 total |
|
Length Matching |
1467 – 1943 mils DP: 10 mils max |
1353 – 1817 mils DP: 10 mils max |
Single-Ended: 1027 – 1319 mils Transceivers: 853 – 1210 mils |